GB BU 0540 SK 500E Brief instructions for frequency inverters
SK 500E – Brief instructions for frequency inverters 10 BU 0540 GB-1013 1.1.2 List of Safety and installation information DANGER Danger of el
1 Overview BU 0540 GB-1013 11 CAUTION Danger of burns The heat sink and all other metal components can heat up to temperatures above 70°C. Touch
SK 500E – Brief instructions for frequency inverters 12 BU 0540 GB-1013 2. Assembly and installation SK 500E frequency inverters are available i
2 Assembly and installation BU 0540 GB-1013 13 E 2.1 SK 5xxE, standard version Normally, the frequency inverter is mounted directly on the rear
SK 500E – Brief instructions for frequency inverters 14 BU 0540 GB-1013 2.2 Electrical connections WARNING THESE DEVICES MUST BE EARTHED. Saf
2 Assembly and installation BU 0540 GB-1013 15 Size 1 - 4 Size 5 - 7 Above size 8 9 = communication CAN/CANopen; RS232/RS485 à X9/X10; X11
SK 500E – Brief instructions for frequency inverters 16 BU 0540 GB-1013 In addition, EMC-compliant wiring must be ensured. If required, an optio
2 Assembly and installation BU 0540 GB-1013 17 Jumper “A” mains input Size 1 - 4 = Operation in IT network = Position 1 (reduced leakage cur
SK 500E – Brief instructions for frequency inverters 18 BU 0540 GB-1013 Adaptation above size 8 The adaptation to the IT network is carried out
2 Assembly and installation BU 0540 GB-1013 19 Connection data: Frequency inverter BG 1 ... 4 Size 5 Size 6 Size 7 Size 8 Size 9 Rigid cabl
SK 500E – Brief instructions for frequency inverters 2 BU 0540 GB-1013 Pos: 2 /A nleit ungen /Ele ktroni k/FU un d Starter /0. Prolog/ 0.1 Si ch
SK 500E – Brief instructions for frequency inverters 20 BU 0540 GB-1013 For multiple motor operation the total motor cable length consists of the
2 Assembly and installation BU 0540 GB-1013 21 NOTICE Total currents 5V / 15V (24V) can be obtained from several terminals if required. With size
SK 500E – Brief instructions for frequency inverters 22 BU 0540 GB-1013 Terminal block X4 – Analog I/O Relevance SK 500E SK 505E SK 510E SK
2 Assembly and installation BU 0540 GB-1013 23 Terminal block X5 – Digital In Relevance SK 500E SK 505E SK 510E SK 511E SK 515E SK 520E SK 530E
SK 500E – Brief instructions for frequency inverters 24 BU 0540 GB-1013 Relevance SK 500E SK 505E SK 510E SK 511E SK 515E SK 520E SK 530E SK 5
2 Assembly and installation BU 0540 GB-1013 25 Terminal block X6 – Encoder Relevance SK 500E SK 505E SK 510E SK 511E SK 515E SK 520E SK 530E
SK 500E – Brief instructions for frequency inverters 26 BU 0540 GB-1013 Relevance SK 500E SK 505E SK 510E SK 511E SK 515E SK 520E SK 530E
2 Assembly and installation BU 0540 GB-1013 27 Control block X9 and X10 – CAN / CANopen Relevance SK 500E SK 505E SK 510E SK 511E SK 515E S
SK 500E – Brief instructions for frequency inverters 28 BU 0540 GB-1013 Plug connector block X11 – RS485 / RS232 Relevance SK 500E SK 505E SK
2 Assembly and installation BU 0540 GB-1013 29 Terminal block X12 – 24 VDC input (only size 5 … 7) Relevance SK 500E SK 505E SK 510E SK 511E
Intended use of the frequency inverter BU 0540 GB-1013 3 Intended use of the frequency inverter Compliance with the operating instructions is n
SK 500E – Brief instructions for frequency inverters 30 BU 0540 GB-1013 Terminal block X15 – motor PTC and 24V input (above size 8) Relevance S
2 Assembly and installation BU 0540 GB-1013 31 Incremental encoder According to the resolution (pulse number), incremental encoders generate a de
SK 500E – Brief instructions for frequency inverters 32 BU 0540 GB-1013 3. Displays and control As delivered, without the technology unit, 2 LED
3 Displays and control BU 0540 GB-1013 33 3.2 Overview of technology units Detailed information about the options listed below can be found in
SK 500E – Brief instructions for frequency inverters 34 BU 0540 GB-1013 Note USS Bus modules and Modbus RTU No optional modules are required for
4 Commissioning BU 0540 GB-1013 35 4. Commissioning Once the power supply has been connected to the frequency inverter, it will be operational w
SK 500E – Brief instructions for frequency inverters 36 BU 0540 GB-1013 RECOMMENDATION: For the correct operation of the drive unit, it is neces
4 Commissioning BU 0540 GB-1013 37 P0-- Display parameters _ _ _ _ P1-- Basic parameter P2-- Motor data P4-- Control terminals P5-- Additional
SK 500E – Brief instructions for frequency inverters 38 BU 0540 GB-1013 5. Parameters Every frequency inverter is factory-set for a motor of the
5 Parameters BU 0540 GB-1013 39 Overview of parameters, user settings (P) ⇒ Parameter set-dependent, these parameters can be differently adjust
SK 500E – Brief instructions for frequency inverters 4 BU 0540 GB-1013 Validity The following brief instructions are based on the main instructi
SK 500E – Brief instructions for frequency inverters 40 BU 0540 GB-1013 Parameter No. [Array] Name Factory setting Super-visor Setting after comm
5 Parameters BU 0540 GB-1013 41 Parameter No. [Array] Name Factory setting Super-visor Setting after commissioning P 1 P 2 P 3 P 4 P407 Adjus
SK 500E – Brief instructions for frequency inverters 42 BU 0540 GB-1013 Parameter No. [Array] Name Factory setting Super-visor Setting after comm
5 Parameters BU 0540 GB-1013 43 Parameter No. [Array] Name Factory setting Super-visor Setting after commissioning P 1 P 2 P 3 P 4 P475 [-02]
SK 500E – Brief instructions for frequency inverters 44 BU 0540 GB-1013 Parameter No. [Array] Name Factory setting Super-visor Setting after comm
5 Parameters BU 0540 GB-1013 45 Parameter No. [Array] Name Factory setting Super-visor Setting after commissioning P 1 P 2 P 3 P 4 P523 Facto
SK 500E – Brief instructions for frequency inverters 46 BU 0540 GB-1013 Parameter No. [Array] Name Factory setting Super-visor Setting after comm
5 Parameters BU 0540 GB-1013 47 Parameter No. [Array] Name Factory setting Super-visor Setting after commissioning P 1 P 2 P 3 P 4 P613 [-18]
SK 500E – Brief instructions for frequency inverters 48 BU 0540 GB-1013 Parameter No. [Array] Name Factory setting Super-visor Setting after comm
5 Parameters BU 0540 GB-1013 49 Parameter No. [Array] Name Actual status and displayed values INFORMATION, read only P720 Actual Torque current
Publisher BU 0540 GB-1013 5
SK 500E – Brief instructions for frequency inverters 50 BU 0540 GB-1013 6. Operating status messages According to the cause, motor controllers a
6 Operating status messages BU 0540 GB-1013 51 SimpleBox / ControlBox display The SimpleBox or ControlBox displays an error with its number and
SK 500E – Brief instructions for frequency inverters 52 BU 0540 GB-1013 E003 3.0 Overcurrent, I2t limit Inverter: I2t limit has triggered, e.g.
6 Operating status messages BU 0540 GB-1013 53 E007 7.0 Mains phase error Mains connection fault • A mains phase is not connected • Mains asym
SK 500E – Brief instructions for frequency inverters 54 BU 0540 GB-1013 10.8 Option error External module communication failure • Connection fa
6 Operating status messages BU 0540 GB-1013 55 13.5 Reserved Error message for POSICON à see supplementary instructions 13.6 Reserved Error m
SK 500E – Brief instructions for frequency inverters 56 BU 0540 GB-1013 Warning messages Display in the SimpleBox / ControlBox Warning Text in t
6 Operating status messages BU 0540 GB-1013 57 C008 8.0 Parameter loss Warning: One of the cyclically saved messages such as operating hours or
SK 500E – Brief instructions for frequency inverters 58 BU 0540 GB-1013 Switch-on block messages Display in the SimpleBox / ControlBox Reason:
7 Technical data BU 0540 GB-1013 59 7. Technical data Pos: 43 6 /Anlei tung en/7. /8. Tech nisc he Daten [ BU 0500/ BU 0200] /SK 5 xxE/7. 1 Al
SK 500E – Brief instructions for frequency inverters 6 BU 0540 GB-1013 Pos: 10 /A nl eitu nge n/St eu ermo dul e/In hal ts verzei ch nis @ 0 \
SK 500E – Brief instructions for frequency inverters 60 BU 0540 GB-1013 8. Maintenance and servicing information Pos: 46 0 /Anlei tung en/El ekt
8 Maintenance and servicing information BU 0540 GB-1013 61 8.2.1 Repairs The device must be sent to the following address if it needs repairing:
SK 500E – Brief instructions for frequency inverters 62 BU 0540 GB-1013 Pos: 46 4 /Anlei tung en/St euerm odul e/Stic hwort verz eichni s @ 0\m
Key word index BU 0540 GB-1013 63 Switch-on cycles ... 59 T Technical data ...
6075402 / 1013
Table of Contents BU 0540 GB-1013 7 Pos: 12 /A nl eitu nge n/St eu ermo dul e/A bbil du ngs verz eic hnis @ 0\ mod_1317978515699_388.docx @ 3
SK 500E – Brief instructions for frequency inverters 8 BU 0540 GB-1013 1. Overview Properties of the basic frequency inverter SK 500E: • High s
1 Overview BU 0540 GB-1013 9 1.1 Safety and installation information NORD frequency inverters are equipment for use in industrial high voltage
Komentarze do niniejszej Instrukcji